EXIOBASE2 Data Download

EXIOBASE2 are only available on request now. The Terms of Use stipulate that licenses are single user, data cannot be transferred or (re-)sold, also if they have been transformed or adapted.

archive MrIOT IxI fpa coefficient version2 2 2

By In EXIOBASE2 (year 2007) full data set 6338 downloads

version 2.2.2
========================

Public version

Includes all data delivered until 1 June 2014. Only the trade fraction data (import & export fractions) are from the version 2.1 database.

Trade linking and balancing to a mimumum sum of absolute deviation between requested column and row headers and calculated row and column headers is about 1E-6 million Euro.

Industry by Industry, fixed product sales assumption, coefficient form


Updates
=======
- Reduced resolution of the energy extensions in mrFDMaterials annd mrMaterials


Format of the files
===================

Text between double quotes
Delimiter tab character
EOL windows format
In the "types_version2.2.2.xls" the full description of all classifications is given including the order of all the classifications.


Pecularities
============

In the emission files there is a row for every substance combined with the air compartment as well as the water compartment while in many cases there are no data available.


Sizes (rows x columns) of the matrices in the files
===================================================

mrIOT (7826 x 7827)
row 1: text, CountryCode
row 2: text, IndustryTypename
column 1: text, CountryCode
column 2: text, IndustryTypeName
column 3: text, UnitCode

mrFinalDemand 7826 x 339
row 1: text, CountryCode
row 2: text, FinalDemandTypeName
column 1: text, CountryCode
column 2: text, IndustryTypeName
column 3: text, UnitCode

mrFactorInputs 21 x 7826
row 1: text, CountryCode
row 2: text, IndustryTypeName
column 1: text, FactorInputTypeName
column 2: text, UnitCode

mrEmissions 172 x 7827
row 1: text, CountryCode
row 2: IndustryTypeName
column 1: text, SubstanceName
column 2: text, CompartmentName
column 3: text, UnitCode

mrResources 17 x 7827
row 1: text, CountryCode
row 2: text, IndustryTypeName
column 1: text, ExtractionTypeName
column 2: text, CompartmentName
column 3: text, UnitCode

mrMaterials 286 x 7826
row 1: text, CountryCode
row 2: text, IndustryTypeNames
column 1: text, PhysicalTypeName
column 2: text, UnitCode

mrFDEmissions 172 x 339
row 1: text, CountryCode
row 2: text, FinalDemandTypeName
column 1: text, SubstanceName
column 2: text, CompartmentName
column 3: text, UnitCode

mrFDMaterials 286 x 338
row 1: text, CountryCode
row 2: text, FinalDemandTypeCode
column 1: text, PhysicalTypeName
column 2: text, UnitCode

archive MrIOT PxP ita coefficient version2 2 2

By In EXIOBASE2 (year 2007) full data set 1268 downloads

version 2.2.2
=============

Public version

Includes all data delivered until 1 June 2014. Only the trade fraction data (import & export fractions) are from the version 2.1 database.

Trade linking and balancing to a mimumum sum of absolute deviation between requested column and row headers and calculated row and column headers is about 1E-6 million Euro.

Product by product, industry sales assumption, coefficient form

Updates
=======
- Corrected accidentally deleted row in the mrMaterial_version2.2.2.txt file. The row that was deleted in the version2.2.1 file was
"Domestic Extraction Used - Primary Crops - Rice"
- Reduced resolution of the energy extensions in mrFDMaterials annd mrMaterials

Format of the files
===================

Text between double quotes
Delimiter tab character
EOL Windows format
In the "types_version2.2.2.xls" the full description of all classifications is given including the order of all the classifications.


Pecularities
============

In the emission files there is a row for every substance combined with the air compartment as well as the water compartment while in many cases there are no data available.


Sizes (rows x columns) of the matrices in the files
===================================================

mrIOT.txt 9602 x 9603
row 1: text, CountryCode
row 2: text, ProductTypename
column 1: text, CountryCode
column 2: text, ProductTypeName
column 3: text, UnitCode

L_inverse.txt 9600 x 9600
no row and column labels
same order as in mrIOT

mrFinalDemand.txt 9602 x 339
row 1: text, CountryCode
row 2: text, FinalDemandTypeName
column 1: text, CountryCode
column 2: text, ProductTypeName
column 3: text, UnitCode

mrFactorInputs.txt 21 x 9602
row 1: text, CountryCode
row 2: text, ProductTypeName
column 1: text, FactorInputTypeName
column 2: text, UnitCode

mrEmissions 172 x 9603
row 1: text, CountryCode
row 2: ProductTypeName
column 1: text, SubstanceName
column 2: text, CompartmentName
column 3: text, UnitCode

mrResources 17 x 9603
row 1: text, CountryCode
row 2: text, ProductTypeName
column 1: text, ExtractionTypeName
column 2: text, CompartmentName
column 3: text, UnitCode

mrMaterials 286 x 9602
row 1: text, CountryCode
row 2: text, ProductTypeName
column 1: text, PhysicalTypeName
column 2: text, UnitCode

mrFDEmissions 172 x 339
row 1: text, CountryCode
row 2: text, FinalDemandTypeName
column 1: text, SubstanceName
column 2: text, CompartmentName
column 3: text, UnitCode

mrFDMaterials 286 x 338
row 1: text, CountryCode
row 2: text, FinalDemandTypeCode
column 1: text, PhysicalTypeName
column 2: text, UnitCode

archive MrSUT version2 2 2

By In EXIOBASE2 (year 2007) full data set 998 downloads

version 2.2.2
========================

Public version

Includes all data delivered until 1 June 2014. Only the trade fraction data (import & export fractions) are from the version 2.1 database.

Trade linking and balancing to a mimumum sum of absolute deviation between requested column and row headers and calculated row and column headers is about 1E-6 million Euro.

Supply-Use Format


Updates
=======
- Reduced resolution of the energy extensions in mrFDMaterials annd mrMaterials


Format of the files
===================

Text between double quotes
Delimiter tab character
EOL Windows format
In the "types_version2.2.2.xls" the full description of all classifications is given including the order of all the classifications.


Pecularities
============

In the emission files there is a row for every substance combined with the air compartment as well as the water compartment while in many cases there are no data available.
In the material files there is still space for N and P load data while no data are available.


Sizes of the matrices in the files
==================================

mrUse 9602 x 7827
row 1: text, CountryCode
row 2: text, IndustryTypeName
column 1: text, CountryCode
column 2: text, ProductTypeName
column 3: text, UnitCode

mrSupply 9602 x 7827
row 1: text, CountryCode
row 2: text, IndustryTypeName
column 1: text, CountryCode
column 2: text, ProductTypeName
column 3: text, UnitCode

mrFinalDemand 9602 x 339
row 1: text, CountryCode
row 2: text, FinalDemandTypeName
column 1: text, CountryCode
column 2: text, ProductTypeName
column 3: text, UnitCode

mrFactorInputs 21 x 7826
row 1: text, CountryCode
row 2: text, IndustryTypeName
column 1: text, FactorInputTypeName
column 2: text, UnitCode

mrEmissions 172 x 7827
row 1: text, CountryCode
row 2: IndustryTypeName
column 1: text, SubstanceName
column 2: text, CompartmentName
column 3: text, UnitCode

mrResources 17 x 7827
row 1: text, CountryCode
row 2: text, IndustryTypeName
column 1: text, ExtractionTypeName
column 2: text, CompartmentName
column 3: text, UnitCode

mrMaterials 286 x 7826
row 1: text, CountryCode
row 2: text, IndustryTypeNames
column 1: text, PhysicalTypeName
column 2: text, UnitCode

mrFDEmissions 172 x 339
row 1: text, CountryCode
row 2: text, FinalDemandTypeName
column 1: text, SubstanceName
column 2: text, CompartmentName
column 3: text, UnitCode

mrFDMaterials 286 x 338
row 1: text, CountryCode
row 2: text, FinalDemandTypeCode
column 1: text, PhysicalTypeName
column 2: text, UnitCode

There is extensive documentation available in the Publications section.